Warning: mysql_connect(): User root already has more than 'max_user_connections' active connections in /www/dentis/dentisimplant.co.kr_201404/common/lib/dbcon.php on line 82 Warning: mysql_select_db() expects parameter 2 to be resource, boolean given in /www/dentis/dentisimplant.co.kr_201404/common/lib/dbcon.php on line 84 Warning: mysql_query(): Access denied for user 'root'@'localhost' (using password: NO) in /www/dentis/dentisimplant.co.kr_201404/common/lib/dbcon.php on line 86 Warning: mysql_query(): A link to the server could not be established in /www/dentis/dentisimplant.co.kr_201404/common/lib/dbcon.php on line 86 Warning: mysql_query(): Access denied for user 'root'@'localhost' (using password: NO) in /www/dentis/dentisimplant.co.kr_201404/common/lib/dbcon.php on line 87 Warning: mysql_query(): A link to the server could not be established in /www/dentis/dentisimplant.co.kr_201404/common/lib/dbcon.php on line 87 Warning: mysql_query(): Access denied for user 'root'@'localhost' (using password: NO) in /www/dentis/dentisimplant.co.kr_201404/common/lib/dbcon.php on line 88 Warning: mysql_query(): A link to the server could not be established in /www/dentis/dentisimplant.co.kr_201404/common/lib/dbcon.php on line 88 Warning: mysql_query() expects parameter 2 to be resource, boolean given in /www/dentis/dentisimplant.co.kr_201404/common/lib/dbcon.php on line 103 Warning: mysql_error() expects parameter 1 to be resource, boolean given in /www/dentis/dentisimplant.co.kr_201404/common/lib/dbcon.php on line 104 Warning: mysql_close() expects parameter 1 to be resource, boolean given in /www/dentis/dentisimplant.co.kr_201404/common/lib/dbcon.php on line 141 Cleanlant(s-Clean) | Dentis Implant | Dental Implant Solution
  • Corporate

  • Dental Implant

  • Surgical Light

  • 3D Printer

  • Bio

  • Dicaon 4D

Cleanlant

  • Home
  • Products
  • Cleanlant

Features of CLEANLANT

  • 1 Platform switching

    • Platform switching helps to minimize bone loss that can reduce peak-stress and thereby preserve marginal bone.
    • Effective to establish a certain biological width of the peri-implant mucosa
    Platform switching
  • 2 Hermetic sealing

    • Hermetic sealing between fixture and abutment
      ensures even distribution of
      the load and minimizes the micro movement and
    Syncronised wide thread
  • 3 Self tapping groove

    • Self tapping induction with a boosted up drilling capability
    • Allow space for bone chip, boosting fixation strength
    Self tapping groove
  • 4 Dome End

    • Less perforation possibility

    Straight Body & Apex 5degree Tapered Design

    • Smooth insertion in any bone type with less bone stress
    • Stable insertion in drilling hole
    Dome End

    Optimum RBM surface

    • Optimised 1.3-1.8㎛ of roughness
    • 192% enhanced magnification than smooth surface.
    Optimum RBM surface

    Double Thread Design

    • Double Thread design will reduce chair time
    Double Thread Design